Specifications |
|
Voltage AC |
APPA A7, A7D
Range: 600V
Basic Accuracy: +/-(1.5%+3d)
APPA A5, A8
Range: 200.0V (A5), 750V
Basic Accuracy: +/-(1.5%+3d)
APPA A7A, A9, A6
Range: 1.0~750.0V
Basic Accuracy: +/-(1.5%+3d)
APPA A7, A7D
Overload Protection: 600V DC Or AC Rms
APPA A5, A7A, A8, A9, A6, A6D, A6DR
Overload Protection: 750V Rms
Conversion Type: Average Sensing RMS Indicating
|
Voltage DC |
APPA A7, A7D
Range: 600V
Basic Accuracy: +/-(1.0%+2d)
APPA A5, A8
Range: 200.0V (A5), 1000V
Basic Accuracy: +/-(1.0%+3d)
APPA A7A, A9, A6, A6D, A6DR
Range: 1.5~999.9V, -0.2V~-999.9V
Basic Accuracy: +/-(1.0%+2d)
APPA A7, A7D
Overload Protection: 600V DC Or AC Rms
APPA A5, A7A, A8, A9, A6, A6D, A6DR
Overload Protection: 1000V DC Or AC Peak
|
Current AC |
APPA A7, A7D, A5, A8
Range: 200.0A
Basic Accuracy: +/-(3.0%+3d) 45Hz~66Hz
APPA A7A
Range: 0.3A~200.0A
Basic Accuracy: +/-(1.8%+3d) 50Hz~60Hz
APPA A9
Range: 0.3A~400.0A
Basic Accuracy: +/-(1.8%+3d) 50Hz~60Hz
APPA A6, A6D, A6DR
Range: 0.3A~600.0A
Basic Accuracy: +/-(2.0%+1A) 50Hz~60Hz
Conversion Type: Average Sensing RMS Indicating
|
Resistance |
APPA A7, A7D, A5, A8
Range: 2000?
Basic Accuracy: +/-(1.0%+2d)
APPA A7A, A9, A6, A6D, A6DR
Range: 2000?
Basic Accuracy: +/-(2.0%+2d)
Overload Protection: 600V Rms
|
Continuity Beeper |
APPA A7, A7D, A8
Threshold: <25?
APPA A5
Threshold: <100?
APPA A7A, A9, A6, A6D, A6DR
Threshold: <200?
Indicator: 2kHz Tone Buzzer
|
Diode Test |
APPA A7, A7D, A5, A8, A7A, A9, A6, A6D, A6DR
Open Circuit Voltage: 3V
|
|
Gerneral Specifications |
|
Sampling Rate |
APPA A7, A7D, A5, A8
2.5 Times/Sec
APPA A7A, A9, A6
5 Times/Sec
|
Overload Indication |
APPA A7, A7D, A5, A8
OL Is Displayed For "A" And "?" Functions. Show The Real Value For "V"
Function
APPA A7A, A9, A6
"OL" Or "-OL"
|
Low Battery Indication |
|
Auto Power Off |
Approx. 30 Minutes
|
Operating Temperature |
-20?~ 50?, <80% RH
|
Sotreage Temperature |
-20?~ 60?
|
Temperature Coefficient |
0.15(Spec. Acc)/?, <18? Or >28?
|
Safety |
APPA A7, A7D
CAT. III 600V
APPA A8, A9, A6
CAT. III 600V/ CAT. II 1000V
APPA A5, A7A
CAT. IV 600V/ CAT.III 1000V
IEC61010 And Designed To Meet UL61010 Specifications
|
Maximum Conductor Size |
APPA A7
12mm Dia.
APPA A7D, A7A, A5
16mm Dia.
APPA A8
23mm Dia.
APPA A9
27mm Dia.
APPA A6
32mm Ida.
|
Maximum Jaw Opening |
APPA A7
12mm Dia.
APPA A7D, A7A, A5
16mm Dia.
APPA A8
28mm Dia.
APPA A9
35mm Dia.
APPA A6
38mm Ida.
|
Power Requirement |
Single 9V Battery (NEDA 1604 Or IEC 6F22)
|
Battery Life |
APPA A7, A7D, A7A, A5, A9, A6
250 Hours (Alkaline Battery)
APPA A8
300 Hours (Alkaline Battery)
|
Size |
APPA A7
65mm (W) X 185mm (L) X 40mm (H)
APPA A7D, A7A
84mm (W) X 175mm (L) X 31mm (H)
APPA A5, A8, A9
66mm (W) X 198mm (L) X 46mm (H)
APPA A6
83mm (W) X 200mm (L) X 48mm (H)
|
Weight |
APPA A7, A7D, A5, A7A
280 Grams
APPA A8, A9
260 Grams
APPA A6
375 Grams
|
Included With Instrument |
APPA A7, A7D, A5, A7A, A8, A9
Test Leads, ZnC Battery (Installed) And Manual
APPA A6
Also Included With Deluxe Carrying Case
|
|