The DT4256 is a digital multimeter designed to deliver maximum functionality for use in a wide range of settings.
Key Features
• Multi functions
• ±0.3% DC V basic accuracy, wide 40 Hz to 1 kHz AC V frequency characteristics
• Low-pass filter (100 Hz/ 500 Hz) cuts high harmonics(when measuring inverter fundamental waveforms)
• Connect to PC with USB communication function (optional)
• Broad -25°C (-13°F) to 65°C (149°F) operating temperature range CAT IV 600 V, CAT III 1000 V
DC Voltage | 600.0 mV to 1000 V, 5 ranges Basic accuracy: ±0.3 % rdg. ±3 dgt. |
---|---|
AC Voltage | 6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz to 1 kHz Basic accuracy 40 - 500 Hz : ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3) |
AUTO AC/DCV | Yes |
Resistance | 600.0 Ω to 60.00 MΩ, 6 ranges, Basic accuracy: ±0.7 % rdg. ±3 dgt. |
DC Current | 60.00 mA to 10.00 A, 4 ranges, Basic accuracy: ±0.9 % rdg. ±3 dgt. |
AC Current | 600.0 mA to 10.00 A, 3 ranges, Basic accuracy 40 - 500 Hz : ±1.4 % rdg. ±3 dgt. (True RMS, crest factor 3, 40 Hz to 1 kHz) |
AC Current (use with Clamp on probes) | 10.00 A to 1000 A, 7 ranges, Add the Clamp on probe accuracy to basic accuracy 40 - 1 kHz : ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3) |
Voltage detection (50/60 Hz) | Hi: AC40 V to 600 V, Lo: AC80 V to 600 V |
C (capacitance) | 1.000 μF to 10.00 mF, 5 ranges, Basic accuracy: ±1.9 % rdg. ±5 dgt. |
Frequency | 99.99 Hz (5 Hz or more) to 99.99 kHz, 4 ranges (limited by the minimum detectable voltage and current), Basic accuracy: ±0.1 % rdg. ±1 dgt. |
Continuity check | Continuity threshold [ON]: 25 Ω or less (Indicate buzzer sound, red LED), [OFF]: 245 Ω or more, Response time: 0.5 ms or more |
Diode test | Open terminal voltage: 5.0 V or less, Testing current 0.5 mA or less, Threshold of forward voltage: 0.15 V to 1.5 V |
Other functions | Filter function, Display value hold, Auto hold, Max/Min/Average value display, Relative display, Auto-power save, USB communication (option) |
Display | Main and Sub displays: 4-digits LCD, max. 6000 digits, bar graph |
Display refresh rates | 5 times/s (Capacitance measurement: 0.05 to 5 times/s, depending on measured value, Frequency: 1 to 2 time/s, Temperature: 1 time/s ) |
Power supply | LR03 alkaline batteries ×4, Continuous use: 130 hours (backlight OFF) |
Dimensions and mass | 84 mm (3.31 in)W × 174 mm (6.85 in)H× 52 mm (2.05 in)D, 390 g (13.8 oz) (including batteries and holster) |
Accessories | Test lead L9207-10 ×1, Holster ×1, Instruction manual ×1, LR03 alkaline battery ×4 |
Multifunctional digital multimeter
・ DC current 60.00mA / 600.0mA / 6.000A / 10.00A ・ Accepts an AC clamp sensor. ・ Voltage detection function
Measurement data can be downloaded to, reviewed on, and saved to a computer.
If you connect the DT4256 to a computer with the optional Communication Package DT4900-01, you can graph data stored in the instrument’s internal memory and display measurement results in real time on the computer. In addition, displayed measured values can be saved (in text format). *The computer and multimeter are electrically isolated by means of optical communications so that data can be sent without concern for electrical hazards.
True RMS measurement for accurate measurement of even distorted current waveforms
Digital multimeters implement two types of measurement: mean-value measurement and true RMS measurement. The two methods yield significantly different measurement results for current waveforms, which are often distorted. For accurate measurement, it is necessary to use an instrument with true RMS capability.
Designed and manufactured in Japan to ensure high quality and guaranteed with a 3-year warranty for peace of mind
All development, design, and manufacturing processes for almost all Hioki digital multimeters are carried out at our Head Office in Nagano Prefecture. Some of the industry’s most advanced technological capabilities enable us to deliver products of the highest possible quality.
Safe measurement requires use of an instrument that suits the measurement location.
To ensure operators’ ability to use measuring instruments safely, IEC 61010 classifies the locations in which instruments are used into a series of safety-based measurement categories (ranging from CAT II to CAT IV). Using an instrument that does not satisfy the required safety level can lead to an electrical accident.
(DT4256)
DC Voltage | 600.0 mV to 1000 V, 5 ranges Basic accuracy: ±0.3 % rdg. ±3 dgt. |
---|---|
AC Voltage | 6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz to 1 kHz Basic accuracy 40 - 500 Hz : ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3) |
AUTO AC/DCV | Yes |
Resistance | 600.0 Ω to 60.00 MΩ, 6 ranges, Basic accuracy: ±0.7 % rdg. ±3 dgt. |
DC Current | 60.00 mA to 10.00 A, 4 ranges, Basic accuracy: ±0.9 % rdg. ±3 dgt. |
AC Current | 600.0 mA to 10.00 A, 3 ranges, Basic accuracy 40 - 500 Hz : ±1.4 % rdg. ±3 dgt. (True RMS, crest factor 3, 40 Hz to 1 kHz) |
AC Current (use with Clamp on probes) | 10.00 A to 1000 A, 7 ranges, Add the Clamp on probe accuracy to basic accuracy 40 - 1 kHz : ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3) |
Voltage detection (50/60 Hz) | Hi: AC40 V to 600 V, Lo: AC80 V to 600 V |
C (capacitance) | 1.000 μF to 10.00 mF, 5 ranges, Basic accuracy: ±1.9 % rdg. ±5 dgt. |
Frequency | 99.99 Hz (5 Hz or more) to 99.99 kHz, 4 ranges (limited by the minimum detectable voltage and current), Basic accuracy: ±0.1 % rdg. ±1 dgt. |
Continuity check | Continuity threshold [ON]: 25 Ω or less (Indicate buzzer sound, red LED), [OFF]: 245 Ω or more, Response time: 0.5 ms or more |
Diode test | Open terminal voltage: 5.0 V or less, Testing current 0.5 mA or less, Threshold of forward voltage: 0.15 V to 1.5 V |
Other functions | Filter function, Display value hold, Auto hold, Max/Min/Average value display, Relative display, Auto-power save, USB communication (option) |
Display | Main and Sub displays: 4-digits LCD, max. 6000 digits, bar graph |
Display refresh rates | 5 times/s (Capacitance measurement: 0.05 to 5 times/s, depending on measured value, Frequency: 1 to 2 time/s, Temperature: 1 time/s ) |
Power supply | LR03 alkaline batteries ×4, Continuous use: 130 hours (backlight OFF) |
Dimensions and mass | 84 mm (3.31 in)W × 174 mm (6.85 in)H× 52 mm (2.05 in)D, 390 g (13.8 oz) (including batteries and holster) |
Accessories | Test lead L9207-10 ×1, Holster ×1, Instruction manual ×1, LR03 alkaline battery ×4 |
SKU | DT4256 |
Brand | Hioki |
Shipping Weight | 0.3900kg |
Be The First To Review This Product!