DT4252 - General Use DMM

Standard Digital Multimeter with Direct Current Input

$326.26
RRP $465.71
SAVE $139.45 (30%)
In Stock


Calculate Shipping



Standard Shipping - $0.00

The DT4252 is a digital multimeter designed specifically for general purpose testing, with ±0.3% DC V accuracy, direct current input and wide 40 Hz to 1kHz bandwidth. DT4252 includes accessories L9207-10 Test Leads, 1 x Holster, 1, Instruction Manual and 4 x LR03 Batteries 

Key Features

• ±0.3% DC V basic accuracy, wide 40 Hz to 1 kHz AC V frequency characteristics

• Low-pass filter (100 Hz/ 500 Hz) cuts high harmonics

• Includes multiple measurement functions such as capacitance, and frequency

• USB communications function supports PC measurements (optional)

• Broad -10 (14°F) to 50°C (122°F) operating temperature range CAT IV 600 V, CAT III 1000 V

DC voltage 600.0 mV to 1000 V, 5 ranges
Basic accuracy: ±0.3 %
rdg. ±5
dgt.
AC voltage 6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz - 1 kHz
Basic accuracy 40 - 500 Hz : ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3)
Resistance 600.0 Ω to 60.00 MΩ, 6 ranges, Basic accuracy: ±0.7 % rdg. ±5 dgt.
DC current 6.000 A / 10.00 A, 2 ranges, Basic accuracy: ±0.9 % rdg. ±5 dgt.
AC current 6.000 A / 10.00 A, 2 ranges,
Basic accuracy 40 - 500 Hz : ±1.4 %
rdg. ±3
dgt.
(True RMS, crest factor 3, 40 Hz to 1 kHz)
AC Current (use with Clamp on probes) N/A
Voltage detection (50/60 Hz) N/A
C (capacitance) 1.000 μF to 10.00 mF, 5 ranges, Basic accuracy: ±1.9 % rdg. ±5 dgt.
Frequency AC V, AC A measurement: 99.99 Hz (5 Hz or more) to 9.999 kHz, 3 ranges, 99.99 kHz (only for AC V)
Basic accuracy: ±0.1 %
rdg. ±1
dgt.
Continuity check Continuity threshold [ON]: 25 Ω or less (Indicate buzzer sound, red LED), [OFF]: 245 Ω or more
Response time: 0.5 ms or more
Diode test Open terminal voltage: 5.0 V or less, Testing current 0.5 mA or less, 
Threshold of forward voltage: 0.15 V to 1.5 V
Other functions Filter function, Display value hold, Auto hold, Max/Min/Average value display, Relative display, Auto-power save, USB communication (option)
Display Main and Sub displays: 4-digits LCD, max. 6000 digits, bar graph
Display refresh rates 5 times/s (Capacitance measurement: 0.05 to 5 times/s, depending on measured value, Frequency: 1 to 2 time/s, Temperature: 1 time/s )
Power supply LR03 alkaline batteries ×4, Continuous use: 130 hours (back light OFF)
Dimensions and mass 84 mm (3.31 in)W × 174 mm (6.85 in)H× 52 mm (2.05 in)D, 390 g (13.8 oz) (with batteries and holster)
Accessories Test lead L9207-10 ×1, Holster ×1, Instruction manual ×1, LR03 alkaline battery ×4

 

Measure output voltage on the secondary sides of inverters by eliminating harmonic components

Accurately measure the fundamental wave alone by eliminating harmonic components with the DMM’s low-pass filter function.

 

 

 

 

 

 

 

 

Measurement data can be downloaded to, reviewed on, and saved to a computer.

If you connect the DT4252 to a computer with the optional Communication Package DT4900-01, you can graph data stored in the instrument’s internal memory and display measurement results in real time on the computer. In addition, displayed measured values can be saved (in text format). *The computer and multimeter are electrically isolated by means of optical communications so that data can be sent with peace of mind.

 

 

 

 

 

 

 

True RMS measurement for accurate measurement of even distorted current waveforms

Digital multimeters implement two types of measurement: mean-value measurement and true RMS measurement. The two methods yield significantly different measurement results for current waveforms, which are often distorted. For accurate measurement, it is necessary to use an instrument with true RMS capability.

 

 

 

Designed and manufactured in Japan to ensure high quality and guaranteed with a 3-year warranty for peace of mind

All development, design, and manufacturing processes for almost all Hioki digital multimeters are carried out at our Head Office in Nagano Prefecture. Some of the industry’s most advanced technological capabilities enable us to deliver products of the highest possible quality.

 

 

 

 

Safe measurement requires use of an instrument that suits the measurement location.

To ensure operators’ ability to use measuring instruments safely, IEC 61010 classifies the locations in which instruments are used into a series of safety-based measurement categories (ranging from CAT II to CAT IV). Using an instrument that does not satisfy the required safety level can lead to an electrical accident.

 

(DT4252)

DC voltage 600.0 mV to 1000 V, 5 ranges
Basic accuracy: ±0.3 % rdg. ±5 dgt.
AC voltage 6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz - 1 kHz
Basic accuracy 40 - 500 Hz : ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3)
Resistance 600.0 Ω to 60.00 MΩ, 6 ranges, Basic accuracy: ±0.7 % rdg. ±5 dgt.
DC current 6.000 A / 10.00 A, 2 ranges, Basic accuracy: ±0.9 % rdg. ±5 dgt.
AC current 6.000 A / 10.00 A, 2 ranges,
Basic accuracy 40 - 500 Hz : ±1.4 % rdg. ±3 dgt.
(True RMS, crest factor 3, 40 Hz to 1 kHz)
AC Current (use with Clamp on probes) N/A
Voltage detection (50/60 Hz) N/A
C (capacitance) 1.000 μF to 10.00 mF, 5 ranges, Basic accuracy: ±1.9 % rdg. ±5 dgt.
Frequency AC V, AC A measurement: 99.99 Hz (5 Hz or more) to 9.999 kHz, 3 ranges, 99.99 kHz (only for AC V)
Basic accuracy: ±0.1 % rdg. ±1 dgt.
Continuity check Continuity threshold [ON]: 25 Ω or less (Indicate buzzer sound, red LED), [OFF]: 245 Ω or more
Response time: 0.5 ms or more
Diode test Open terminal voltage: 5.0 V or less, Testing current 0.5 mA or less, 
Threshold of forward voltage: 0.15 V to 1.5 V
Other functions Filter function, Display value hold, Auto hold, Max/Min/Average value display, Relative display, Auto-power save, USB communication (option)
Display Main and Sub displays: 4-digits LCD, max. 6000 digits, bar graph
Display refresh rates 5 times/s (Capacitance measurement: 0.05 to 5 times/s, depending on measured value, Frequency: 1 to 2 time/s, Temperature: 1 time/s )
Power supply LR03 alkaline batteries ×4, Continuous use: 130 hours (back light OFF)
Dimensions and mass 84 mm (3.31 in)W × 174 mm (6.85 in)H× 52 mm (2.05 in)D, 390 g (13.8 oz) (with batteries and holster)
Accessories Test lead L9207-10 ×1, Holster ×1, Instruction manual ×1, LR03 alkaline battery ×4
SKU DT4252
Brand Hioki
Shipping Weight 0.6500kg
Shipping Width 0.084m
Shipping Height 0.052m
Shipping Length 0.174m
Unit Of Measure ea

Be The First To Review This Product!

Help other Test Equipment Online users shop smarter by writing reviews for products you have purchased.

Write a product review


We Also Recommend


CARRYING CASE 3853

CARRYING CASE 3853

$29.55

8% OFF RRP $32.00
CARRYING CASE C0201

CARRYING CASE C0201

$73.61

COMMUNICATION PACKAGE (USB) DT4900-01
50% OFF RRP $103.11
MAGNETIC STRAP Z5020

MAGNETIC STRAP Z5020

$73.61

32% OFF RRP $107.80
1212202 - Phoenix Combination Pliers 1000V AC
18% OFF RRP $61.00

More From This Category


APPA IMETER5
50% OFF RRP $71.11
APPA 98III

APPA 98III

$143.57

50% OFF RRP $287.13
DT4211 - Entry Level DMM

DT4211 - Entry Level DMM

$180.00

4% OFF RRP $187.00
Conversion Adapter 9704

Conversion Adapter 9704

$58.49

UT71A- Intelligent Digital Multimeter
50% OFF RRP $227.31
UNI-T UT58E

UNI-T UT58E

$58.04

50% OFF RRP $116.09