DT4255 - Electrical DMM

Digital Multimeter

$426.25
RRP $608.92
SAVE $182.67 (30%)
In Stock


Calculate Shipping



Standard Shipping - $0.00

The DT4255 is a digital multimeter designed for maximum safety with voltage measurement terminals that are protected by a fuse.

 

Key Features

• Maximum safety in the field by absolutely preventing short-circuit accidents with fused measurement terminals and current-limiting resistor

• ±0.3% DC V basic accuracy, wide 40 Hz to 1 kHz AC V frequency characteristics

• Low-pass filter (100 Hz/ 500 Hz) cuts high harmonics (when measuring inverter fundamental waveforms)

• Connect to PC with USB communication function (optional)

• Broad -25°C (-13°F) to 65°C (149°F) operating temperature range CAT IV 600 V, CAT III 1000 V

 

 

DC Voltage 600.0 mV to 1000 V
5 ranges, Basic accuracy: ±0.3 % rdg. ±3 dgt.
AC Voltage 6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz to 1 kHz
Basic accuracy 40 - 500 Hz : ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3)
AUTO AC/DCV Yes
Resistance 600.0 Ω to 60.00 MΩ, 6 ranges, Basic accuracy: ±0.7 % rdg. ±3 dgt.
DC Current N/A
From 4 to 20mA Percentage conversion display N/A
AC Current (use with Clamp on probes) 10.00 A to 1000 A, 7 ranges, Add the Clamp on probe accuracy to basic accuracy 40 - 1 kHz : ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3)
Temperature (thermocouples) N/A
Voltage detection Hi: AC40 V to 600 V, Lo: AC80 V to 600 V
C (capacitance) 1.000 μF to 10.00 mF, 5 ranges, Basic accuracy: ±1.9 % rdg. ±5 dgt.
Frequency 99.99 Hz to 99.99 kHz, 4 ranges (limited by the minimum detectable voltage),
Basic accuracy: ±0.1 % rdg. ±1 dgt.
Continuity check Continuity threshold [ON]: 25 Ω or less , 
[OFF]: 245 Ω or more, 
Response time: 0.5 ms or more
Diode test Open terminal voltage: 5.0 V or less, Testing current 0.5 mA or less, 
Threshold of forward voltage: 0.15 V to 1.5 V
Other functions Filter function, Display value hold, Auto hold, Max/Min/Average value display, Relative display, Auto-power save, USB communication (option)
Display Main and Sub displays: 4-digits LCD, max. 6000 digits, bar graph
Display refresh rates 5 times/s (Capacitance measurement: 0.05 to 5 times/s, depending on measured value, Frequency: 1 to 2 time/s)
Power supply LR03 alkaline batteries ×4, Continuous use: 130 hours (backlight OFF)
Dimensions and mass 84 mm (3.31 in)W × 174 mm (6.85 in)H× 52 mm (2.05 in)D,
390 g (13.8 oz) (including batteries and holster)
Accessories Test lead L9207-10 ×1, Holster ×1, Instruction manual ×1, LR03 alkaline battery ×4

 

 

Digital Multimeter designed for maximum safety with fuse-protected terminals

・ Accepts an AC clamp sensor. ・ Voltage detection function

 

 

Thorough prevention of shortcircuit accidents

When using the resistance measurement function, a protective circuit functions to prevent a short-circuit accident in the event of erroneous operation such improperly supplying voltage input. Even if a short-circuit occurs inside the tester, a current-limiting resistor will limit any short-circuit current while a fast-blow fuse quickly and reliably disconnects the tester circuitry, preventing a short-circuit accident.

 

 

 

 

 

 

 

 

Clamp-on sensorbased current measurement eliminates the cause of accidents

Mistakenly measuring voltage using the current range may lead to a short-circuit. The DT4255 eliminates the root cause of such accidents by providing clamp-on sensorbased current measurement functionality instead of using conventional probes.

 

 

 

 

 

Measure output voltage on the secondary sides of inverters by eliminating harmonic components

Accurately measure the fundamental wave alone by eliminating harmonic components with the DMM’s low-pass filter function.

 

 

 

 

 

 

 

Measurement data can be downloaded to, reviewed on, and saved to a computer.

If you connect the DT4255 to a computer with the optional Communication Package DT4900-01, you can graph data stored in the instrument’s internal memory and display measurement results in real time on the computer. In addition, displayed measured values can be saved (in text format). *The computer and multimeter are electrically isolated by means of optical communications so that data can be sent without concern for electrical hazards.

 

 

 

 

 

 

 

 

True RMS measurement for accurate measurement of even distorted current waveforms

Digital multimeters implement two types of measurement: mean-value measurement and true RMS measurement. The two methods yield significantly different measurement results for current waveforms, which are often distorted. For accurate measurement, it is necessary to use an instrument with true RMS capability.

 

 

 

 

 

Designed and manufactured in Japan to ensure high quality and guaranteed with a 3-year warranty for peace of mind

All development, design, and manufacturing processes for almost all Hioki digital multimeters are carried out at our Head Office in Nagano Prefecture. Some of the industry’s most advanced technological capabilities enable us to deliver products of the highest possible quality.

 

 

 

 

 

 

 

 

Safe measurement requires use of an instrument that suits the measurement location.

To ensure operators’ ability to use measuring instruments safely, IEC 61010 classifies the locations in which instruments are used into a series of safety-based measurement categories (ranging from CAT II to CAT IV). Using an instrument that does not satisfy the required safety level can lead to an electrical accident.

(DT4255)

DC Voltage 600.0 mV to 1000 V
5 ranges, Basic accuracy: ±0.3 % rdg. ±3 dgt.
AC Voltage 6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz to 1 kHz
Basic accuracy 40 - 500 Hz : ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3)
AUTO AC/DCV Yes
Resistance 600.0 Ω to 60.00 MΩ, 6 ranges, Basic accuracy: ±0.7 % rdg. ±3 dgt.
DC Current N/A
From 4 to 20mA Percentage conversion display N/A
AC Current (use with Clamp on probes) 10.00 A to 1000 A, 7 ranges, Add the Clamp on probe accuracy to basic accuracy 40 - 1 kHz : ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3)
Temperature (thermocouples) N/A
Voltage detection Hi: AC40 V to 600 V, Lo: AC80 V to 600 V
C (capacitance) 1.000 μF to 10.00 mF, 5 ranges, Basic accuracy: ±1.9 % rdg. ±5 dgt.
Frequency 99.99 Hz to 99.99 kHz, 4 ranges (limited by the minimum detectable voltage),
Basic accuracy: ±0.1 % rdg. ±1 dgt.
Continuity check Continuity threshold [ON]: 25 Ω or less , 
[OFF]: 245 Ω or more, 
Response time: 0.5 ms or more
Diode test Open terminal voltage: 5.0 V or less, Testing current 0.5 mA or less, 
Threshold of forward voltage: 0.15 V to 1.5 V
Other functions Filter function, Display value hold, Auto hold, Max/Min/Average value display, Relative display, Auto-power save, USB communication (option)
Display Main and Sub displays: 4-digits LCD, max. 6000 digits, bar graph
Display refresh rates 5 times/s (Capacitance measurement: 0.05 to 5 times/s, depending on measured value, Frequency: 1 to 2 time/s)
Power supply LR03 alkaline batteries ×4, Continuous use: 130 hours (backlight OFF)
Dimensions and mass 84 mm (3.31 in)W × 174 mm (6.85 in)H× 52 mm (2.05 in)D,
390 g (13.8 oz) (including batteries and holster)
Accessories Test lead L9207-10 ×1, Holster ×1, Instruction manual ×1, LR03 alkaline battery ×4
SKU DT4255
Brand Hioki
Shipping Weight 0.3900kg

Be The First To Review This Product!

Help other Test Equipment Online users shop smarter by writing reviews for products you have purchased.

Write a product review


We Also Recommend


CARRYING CASE 3853

CARRYING CASE 3853

$29.55

8% OFF RRP $32.00
CARRYING CASE C0201

CARRYING CASE C0201

$73.61

COMMUNICATION PACKAGE (USB) DT4900-01
50% OFF RRP $103.11
MAGNETIC STRAP Z5020

MAGNETIC STRAP Z5020

$73.61

32% OFF RRP $107.80
DT4910  THERMOCOUPLES (K) -40 to 260 °C (-40 to 500 °F)
30% OFF RRP $92.85

Others Also Bought


DT4282 - High End General Use DMM

DT4282 - High End General Use DMM

$795.83

0% OFF RRP $799.00

More From This Category


DT4256 - General Electrical Use DMM
20% OFF RRP $437.50
A5 - APPA OPEN CLAMP MULTIMETER

A5 - APPA OPEN CLAMP MULTIMETER

$154.00

20% OFF RRP $193.00
DT4224 - Entry Level Pocket DMM
10% OFF RRP $277.20
DT4222 - Entry Level DMM

DT4222 - Entry Level DMM

$192.10

10% OFF RRP $214.04
PARAMETERS PA3020

PARAMETERS PA3020

$43.16

50% OFF RRP $86.31
Conversion Adapter 9704

Conversion Adapter 9704

$58.49

APPA IMETER5
50% OFF RRP $71.11
DT4252 - General Use DMM

DT4252 - General Use DMM

$326.26

30% OFF RRP $465.71