LR5011- TEMPERATURE LOGGER

1-channel Temperature Data Logger with -40°C to 180°C

$294.00
In Stock


Calculate Shipping



Standard Shipping - $0.00

Hioki compact 1 or 2-channel data loggers feature a 60,000 data set/channel memory to measure temperature, humidity, voltage or instrumentation signals. The LR5001 logs temperature and humidity over 2 channels in as fast as 1 second intervals.

 

Key Features

• Easily mount the light-weight , pocket-sized loggers in tight spaces

• Easy-to-see dual display

• Transfer data to PC even during recording

• Replace batteries while recording (30 second limit) Note: Recording is interrupted during battery replacement if the battery is very weak. After batteries are replaced, recording resumes automatically. Previously recorded data is not lost during battery replacement.

• 7 times the memory capacity than predecessor (Record 60,000 data per channel)

• Record without missing fluctuations in STAT mode • Measurement data is preserved even after the battery dies

• Worry-free backup preserves recorded data even if a new measurement is started by mistake

Measurement items Temperature 1 ch and Humidity 1 ch (Requires included or optional humidity sensor)
Measurement range Temperature: -40.0 to 85.0 °C, Humidity: 0 to 100 % rh *at sensor environment
Basic accuracy [Temperature] : ±0.5 °C (main unit + sensor accuracy, at 0.0 to 35.0 °C)
[Humidity] : ±5 %
rh (main unit + temperature / humidity sensor LR950x combination, at 20 to 30 °C / 10 to 50 % rh)
Note: Basic accuracy is typical value, refer to the detailed catalog
Storage capacity Instantaneous value mode: 60,000 data, Statistical value mode: 15,000 data
Recording interval 1 to 30 sec., 1 to 60 min., 15 selections
Recording modes Instantaneous recording: at every recording interval
Statistical value recording: Measure at
one second intervals, and record the instantaneous, maximum, minimum, and average values within every recording interval
Recording methods One-time recording: Stop recording when the memory capacity is full
Endless recording: Continue recording even when the memory capacity is full (old data is overwritten)
Start: Logger button operation or scheduled time
Stop: Logger button operation or scheduled time, or auto-stop when the memory capacity is full (at one-time recording)
Other functions Always backs up last recorded data; backs up recorded data and setting conditions when battery power is low
Note: After batteries are replaced within 30 seconds, recording resumes automatically (Recording is interrupted during battery replacement)
Waterproof and dust-proof IP54 (EN60529) (with sensor connected, but not including sensor tip)
Interfaces Infrared optical communications with LR5091, LR5092-20
Power supply LR6 (AA) Alkaline battery × 1, Battery life: Approx. 3 months (Instantaneous recording, with 1-minute interval and auto power saving, at 20 °C), Approx. 20 days (Instantaneous recording, with 1-second interval at 20 °C)
Dimensions and mass 79 mm (3.11 in) W × 57 mm (2.246 in) H × 28 mm (1.10 in) D, 105 g (3.7 oz)
Accessories LR6 (AA) Alkaline battery (built-in internal) × 1, Humidity Sensor LR9504 × 1, Instruction manual × 1, Operation guide × 1, Kickstand × 1
 

(LR5011)

Measurement items Temperature 1ch (with optional sensor)
Measurement range -40.0 °C to 180.0 °C *Depends on measurement range of sensor
Basic accuracy ±0.5 °C (main unit + sensor accuracy, at 0.0 to 35.0 °C)
Note: Basic accuracy is typical value, refer to the detailed catalog
Storage capacity Instantaneous value mode: 60,000 data, Statistical value mode: 15,000 data
Recording interval 1 to 30 sec., 1 to 60 min., 15 selections
Recording modes Instantaneous recording: at every recording interval
Statistical value recording: Measure at
one second
intervals, and record the instantaneous, maximum, minimum, and average values within every recording interval
Recording methods One-time recording: Stop recording when the memory capacity is full
Endless recording: Continue recording even when the memory capacity is full (old data is overwritten)
Start: Logger button operation or scheduled time
Stop: Logger button operation or scheduled time, or auto-stop when the memory capacity is full (at one-time recording)
Other functions Always backs up last recorded data; backs up recorded data and setting conditions when battery power is low; guarantees approx. 30 sec. of recording operation and clock while battery is replaced
Waterproof and dust-proof IP54 (EN60529) (with sensor connected, but not including sensor tip)
Interfaces Infrared optical communications with LR5091, LR5092-20
Power supply LR6 (AA) Alkaline battery × 1, Battery life: Approx. 2 years (Instantaneous recording, with 1-minute interval and auto power saving, at 20 °C), Approx. 2 months (Instantaneous recording, with 1-second interval at 20 °C)
Dimensions and mass 79 mm (3.11 in) W × 57 mm (2.246 in) H × 28 mm (1.10 in) D, 105 g (3.7 oz)
Accessories LR6 (AA) Alkaline battery (built-in internal) × 1, Instruction manual × 1, Operation guide × 1, Kickstand × 1
Measurement items Temperature 1 ch and Humidity 1 ch (Requires included or optional humidity sensor)
Measurement range Temperature: -40.0 to 85.0 °C, Humidity: 0 to 100 % rh *at sensor environment
Basic accuracy [Temperature] : ±0.5 °C (main unit + sensor accuracy, at 0.0 to 35.0 °C)
[Humidity] : ±5 %rh (main unit + temperature / humidity sensor LR950x combination, at 20 to 30 °C / 10 to 50 % 
rh)
Note: Basic accuracy is typical value, refer to the detailed catalog
Storage capacity Instantaneous value mode: 60,000 data, Statistical value mode: 15,000 data
Recording interval 1 to 30 sec., 1 to 60 min., 15 selections
Recording modes Instantaneous recording: at every recording interval
Statistical value recording: Measure
atone second intervals, and record the instantaneous, maximum, minimum, and average values within every recording interval
Recording methods One-time recording: Stop recording when the memory capacity is full
Endless recording: Continue recording even when the memory capacity is full (old data is overwritten)
Start: Logger button operation or scheduled time
Stop: Logger button operation or scheduled time, or auto-stop when the memory capacity is full (at one-time recording)
Other functions Always backs up last recorded data; backs up recorded data and setting conditions when battery power is low
Note: After batteries are replaced within 30 seconds, recording resumes automatically (Recording is interrupted during battery replacement)
Waterproof and dust-proof IP54 (EN60529) (with sensor connected, but not including sensor tip)
Interfaces Infrared optical communications with LR5091, LR5092-20
Power supply LR6 (AA) Alkaline battery × 1, Battery life: Approx. 3 months (Instantaneous recording, with 1-minute interval and auto power saving, at 20 °C), Approx. 20 days (Instantaneous recording, with 1-second interval at 20 °C)
Dimensions and mass 79 mm (3.11 in) W × 57 mm (2.246 in) H × 28 mm (1.10 in) D, 105 g (3.7 oz)
Accessories LR6 (AA) Alkaline battery (built-in internal) × 1, Humidity Sensor LR9504 × 1, Instruction manual × 1, Operation guide × 1, Kickstand × 1
SKU LR5011
Brand Hioki
Shipping Weight 0.1050kg

Be The First To Review This Product!

Help other Test Equipment Online users shop smarter by writing reviews for products you have purchased.

Write a product review


We Also Recommend