LR5092 - DATA COLLECTOR -Wirelessly Transfer Logging Data from a LR5000 Series Data Logger

Wirelessly Transfer Logging Data from a LR5000 Series

$780.27
In Stock


Calculate Shipping



Standard Shipping - $15.00

The Hioki LR5092 is a data collector for wirelessly collecting data from the LR5000 Series Data Loggers. Simply dock the Data Collector onto the data logger to transfer data using infrared, then upload the data to a PC using USB or SD card. A maximum of 60,000 data x 16 channels can be collected up to 500 times on 2 batteries.

 

Key Features

• Bring the data logger LR5000 series back from the field and transfer data to a PC

• Save data from data loggers in the built-in memory or on an SD card (LR5092-20)

• Send settings from a PC to a data logger

• Use the included software to easily graph and print data

• Use the included software to calculate maximum, minimum, and average values and more between cursors

Function Send data from a data logger to the internal memory or an SD card, then display a graph. 
Send settings and the time from the internal memory or SD card to a data logger. 
Send data from a data logger to a PC. 
Send settings and the time from a PC to a data logger.
Communications method Between data loggers: Infrared communications
With PC: USB 2.0
Display Data logger setting conditions
Collected data (as list, graph, values, etc.)
Internal memory (capacity of data) 60,000 data elements ×16ch (instantaneous value mode)
15,000 data elements ×16ch (statistical value mode)
Data logger settings (max. 1 set)
Removable storage media SD memory card
Save data and max. 16 items configuration
Power supply DC 3 V (LR6 (AA) Alkaline battery ×2)
USB bus power (12 hours or 500 times of data collection)
Dimensions and mass 91 mm (3.58 in) W × 141 mm (5.55 in) H × 31 mm (1.22 in) D, 215 g (7.6 oz) (excluding batteries and SD memory card)
Accessories Instruction manual ×1, Operation guide ×1, LR6 (AA) Alkaline battery ×2, USB cable (1 m) ×1, CD (Application software "LR5000 Utility") × 1

â–  LR5000 utility specifications

Operating environment OS: Windows 7 (32/64bit, .NET Framework 2.0 or more), Vista (32bit, SP1 or more), XP (SP2 or more)
*USB interface (when using the Communication Base 3910/3911, a COM port is required)
Function • Settings: Communicates via infrared light with LR5000 series loggers to send and receive settings.
• Graph function: Displays graphs of up to 16 channels, displays statistical data, etc.
• Print function: Print graphs, Print statistical data.
• Export function (data CSV output, paste into Excel)
• Import function (loads text files from the Clamp On Power HiTester 3169-20/-21 [only demand parameter with a recording interval of at least 1 sec.])
• Processing of data: Scaling, Power calculation, Energy cost calculation, Operating ratio calculation, Integration, Dew point temperature, Calculate between channels

(LR5092)

Function Send data from a data logger to the internal memory or an SD card, then display a graph. 
Send settings and the time from the internal memory or SD card to a data logger. 
Send data from a data logger to a PC. 
Send settings and the time from a PC to a data logger.
Communications method Between data loggers: Infrared communications
With PC: USB 2.0
Display Data logger setting conditions
Collected data (as list, graph, values, etc.)
Internal memory (capacity of data) 60,000 data elements ×16ch (instantaneous value mode)
15,000 data elements ×16ch (statistical value mode)
Data logger settings (max. 1 set)
Removable storage media SD memory card
Save data and max. 16 items configuration
Power supply DC 3 V (LR6 (AA) Alkaline battery ×2)
USB bus power (12 hours or 500 times of data collection)
Dimensions and mass 91 mm (3.58 in) W × 141 mm (5.55 in) H × 31 mm (1.22 in) D, 215 g (7.6 oz) (excluding batteries and SD memory card)
Accessories Instruction manual ×1, Operation guide ×1, LR6 (AA) Alkaline battery ×2, USB cable (1 m) ×1, CD (Application software "LR5000 Utility") × 1

â–  LR5000 utility specifications

Operating environment OS: Windows 7 (32/64bit, .NET Framework 2.0 or more), Vista (32bit, SP1 or more), XP (SP2 or more)
*USB interface (when using the Communication Base 3910/3911, a COM port is required)
Function • Settings: Communicates via infrared light with LR5000 series loggers to send and receive settings.
• Graph function: Displays graphs of up to 16 channels, displays statistical data, etc.
• Print function: Print graphs, Print statistical data.
• Export function (data CSV output, paste into Excel)
• Import function (loads text files from the Clamp On Power HiTester 3169-20/-21 [only demand parameter with a recording interval of at least 1 sec.])
• Processing of data: Scaling, Power calculation, Energy cost calculation, Operating ratio calculation, Integration, Dew point temperature, Calculate between channels
SKU LR5092
Brand Hioki
Shipping Weight 0.2150kg

Be The First To Review This Product!

Help other Test Equipment Online users shop smarter by writing reviews for products you have purchased.

Write a product review


More From This Category


9465-90 TIP PIN

9465-90 TIP PIN

$114.00

9% OFF RRP $125.40
AC FLEXIBLE CURRENT SENSOR CT6280

AC FLEXIBLE CURRENT SENSOR CT6280

$235.33

0% OFF RRP $236.50
L4935 ALLIGATOR CLIP SET

L4935 ALLIGATOR CLIP SET

$44.32

COMMUNICATION PACKAGE (USB) DT4900-01
50% OFF RRP $103.11
 L4930 CONNECTION CABLE SET

L4930 CONNECTION CABLE SET

$44.32

CARRYING CASE C0201

CARRYING CASE C0201

$73.61

L9787 - TEST LEAD

L9787 - TEST LEAD

$66.10

CARRYING CASE 3853

CARRYING CASE 3853

$29.55

8% OFF RRP $32.00